Diagnosing the Cause Of, and Avoiding Cupping in Solid Wood Flooring

Cupping or dishing in solid hardwood means the boards raise slightly at their edges
making the hardwood flooring uneven across its width. The cause of cupping is an
imbalance of moisture through the timber. This can be a result of a spillage on the floor,
or as a result of the hardwood flooring gaining moisture from the sub-floor material.

Taking moisture reading of the underside of the timber and comparing this with a reading
taken from the upper side will confirm this.

Wood always expands when it takes on moisture. It therefore follows that moisture on
the underside of the wood will make the underside expand laterally. However, the upper
side of the wood which has not absorbed any moisture, so this stays at near its original
size. The immense strength of the expansion of the underside of the wood is what causes
the edges of the wood curl.

On nearly every incidence of cupping that I have inspected, the flooring was laid onto a
solid floor using adhesive- meaning that the sub-floor was too high moisture content. A
quick and simple way of identifying the problem is by taking a moisture reading of the
sub-floor. Usually this is just a matter of drilling a small hole into the sub-floor between
the gaps in the board, and inserting the probe from a moisture meter. The reading of the
sub-floor should be around 9- 11% moisture content. If it is greater , then this could be
the source of the moisture.

As part of an inspection process, I also look for evidence of leaks from appliances e.g.
dishwashers, and leaks from heating pipes, and poor or zero ventilation in the room.
I also take a reading of the humidity at the time of the inspection, although this is merely
a snapshot of one moment in time and does not necessarily give an indication of the
humidity at an earlier time that may have caused the cupping.

However, another scenario could be that the sub-floor was within the above parameters,
but the wood could have been dried too aggressively before being installed. This could
mean that the sub-floor was at the correct moisture content, but the wood was too dry to
be installed. In a case like this, the humidity needs to be regulated quickly which can
usually stabilize the problem.

How to Rectify the Cupping

Step one is to check the integrity of the fixing of the floor. In extreme cases of buckling,
the flooring can (in the case of adhesive installations), de-bond from the sub-floor. If this
is the case, the floor May be beyond repair if in excess of 40% of the floor area is
affected in this way.

Stabilize the humidity in the room as quickly as possible. If the relative humidity of the
room is below 40% then this is too dry. A correct humidity level is between 45% and
60% R.H. This can be achieved by the use of a humidifier.
It may then ne necessary to have the floor sanded and re-finished, which should then
eliminate any further problems and restore the appearance of the flooring.

It is vital though, that the stabilization is undertaken gradually over a period, and that
thorough moisture readings are taken on both sides of the timber before sanding. If the
floor is sanded before the wood has stabilized, the edges of the board will be lower than
the middle of the boards.

Get It Right Before You Start

If you are about to lay a floor using a stick down method, take thorough moisture checks
of the sub-floor and the humidity of the room that is to be fitted.
The sub-floor should be ideally below 12% moisture content and the humidity of the
room should be between 40% and 60%.

If there is any doubt regarding the integrity of sub-floor, it may be necessary to apply an
epoxy resin damp proof membrane to the sub-floor.

If you are installing using the secret nailing technique, then an impervious layer should
be laid over the sub-floor or battens -e.g. foil, polythene membrane or builders paper.

Make sure that an adequate acclimatization period is allowed for. This is normally
achieved by storing the flooring in the room for at least two weeks prior to installation.
The room should be heated and ventilated in the same conditions that the floor will be
used i.e. temperature and relative humidity.

Final Considerations

1. Tangential cut hardwoods always have greater movement than radial cut or quarter
sawn hardwoods.
2. Narrow width solid hardwoods are always more stable and less prone to movement
than wider width flooring.
3. Engineered flooring will always cope better with fluctuations in moisture, and climate.
4. Wood floors will always move depending on the season- e.g. in winter months slight
opening of joints and cracks are to be expected.

Article Source: http://www.articledestination.com

Alan is the technical manager at Birbek Floors Ltd, a UK distributor of solid oak wood flooring and American walnut flooring www.birbek.com


Please Rate this Article   

Not yet Rated

Click the XML Icon Above to Receive Home Improvement Articles Via RSS!

Additional Articles From - Home | Home Improvement

Top Authors  Most Popular Articles  Submission Guidelines  Ezine Notifications  Article RSS Feeds  About Us  Contact Us  Privacy Policy  Terms of Service

Copyright © 2005-2012  ArticleDestination.com  All Rights Reserved.

hit counter html code

Powered by Article Dashboard